Water as a raw material for making ice cubes should be able to see the requirements contained in SNI 01-3553-2006 Bottled Drinking Water. To note, this SNI requires quality, among others, odorless, dissolved substances max. 500mg/l, organic matter 1.0 mg/l, chloride max. 250 mg/l, sulfate max. 200 mg/l, and ammonium max. 0.15 mg/l. Obviously, ice cubes whose raw water contains a lot of bacteria should not be drunk. it is impossible for ice cubes to be heated first to kill bacteria because it violates its function to cool drinking water. it is feared if it turns out that the ice cubes produced for cooling fish are used for drinking water consumption.

The ice used in PT. Biru Laut Nusantara is an ice crystal that is produced at PT. Murah Kristal Sulawesi, The results of the tests carried out at PT. Murah Kristal Sulawesi as follows.

The report on the results of the ice test used at PT Biru Laut Nusantara
Parameter | Unit | Results | Quality Requirement #) | Test Method |
Smell | – | Tidak Berbau | Tidak Berbau | IK-MT-30.01 |
Total Dissolved Solids (TDS) | mg/L | 196 | 1500 | SNI 6989.27:2019 |
Total Suspended Solids (TSS) | mg/L | 6 | – | SNI 6989.3:2019 |
Taste | – | Tidak Berasa | Tidak Berasa | IK-MT-30-02 |
Colour | TCU | 2,50 | 50 | SNI 06-6989.24-2005 |
Turbidity | Skala NTU | < 0.01 | 25 | SNI 06-6989.25-2005 |
Ferrum (Fe) | mg/L | < 0,03 | 1,0 | SNI 6989.4:2009 |
Cadmium (Cd) | mg/L | < 0,003 | 0,005 | SNI 6989.16:2009 |
Chrome Hexavalent (Cr+6) | mg/L | < 0,0004 | 0,05 | SNI 6989.71:2009 |
pH | – | 7,64 | 6,5-9,0 | SNI 6989.71:2009 |
Cuprum (Cu) | mg/L | < 0,010 | – | SNI 6989.11:2019 |
Plumbum (Pb) | mg/L | < 0,002 | 0,05 | SNI 6989.6:2009 |
Chlorine (Cl2) | mg/L | < 0,02 | – | SNI 06-6989.8-2004 |
Mercury / Hydrargyrum | mg/L | < 0,0003 | 0,001 | Sni 6989.78:2011 |
DO | mg/L | 7,9192 | – | SNI 06-6989.14-2004 |